1-6-5.CLUSTER電軌CLUSTER BAR

商品名稱:

1-6-5.CLUSTER電軌CLUSTER BAR

詳細介紹:

1.C&W電軌系統(SAF-T-BAR)新目錄                                                                        
       1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR)                                               下載down load1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 
       1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)                                               下載down load1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)

       1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR)                                                下載down load1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR)

       1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)                                                  下載down load1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)

       1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)              下載down load1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)

       1-6.CLUSTER電軌CLUSTER BAR                                                                           下載down load 1-6.CLUSTER電軌CLUSTER BAR

Conductor Bar                              
Continuous  roll formed  inverted “V” cross section encased by an insulating  PVC cover. Splice kit included with the price of conductor. Operating Temperature: -10O   F to 160O   F. Bars are 15.0 ft (4.57 m) long

 

Bar Type

Current             Part No. Capacity (A)   (w/Bolted Splice)

Part No. (w/Crimped Splice)

 

Wt lb (kg)

Galvanized Steel

40                28656

28101

2.0 (0.91)

Rolled Copper

120               28655

28100

2.0 (0.91)

Expansion Section                       
Factory assembled with overlapping design to provide continuous contact with collector shoes to compensate for thermal expansion. Power feeds are flexible jumpers installed to for 40A steel conductor and 96’ for 120A copper conductor. Length: 6 ft. (1.83m)meet electrical and mechanical requirements. Spacing for expansion sections is every 141’

 

Bar Type

Current             Part No. Capacity (A)   (w/Bolted Splice)

Part No. (w/Crimped Splice)

Wt lb

(kg)

Galvanized Steel

40                28658

28104

6.0 (2.72)

Rolled Copper

120               28657

28103

7.0 (3.72)

Power feed                                 
Provides the electrical connection from power source to the conductor bar.  It may be located at any point along the conductor, preferably near the systems' center to reduce voltage drop.

Connection Wire

Size (AWG)

Part

No.

 

Wt lb (kg)

10

28067

0.4 (0.18)

6

28066

0.4 (0.18)

End Power Feed
Provides the electrical connection from the power source to the conductor bar. This power feed attaches to the end of the bar.

Connection Wire Size

Part No.

Wt lbs.

#8 AWG

29836

0.2 (0.09)

#10 AWG

29837

0.2 (0.09)

End Cover                                     
Two-piece polypropylene boot used to close off the open ends of the conductor bar.

Part No.    Wt lb (kg)

28105        0.3 (0.14)