商品名稱:
4-8.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM -08
詳細介紹:
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down load

For syslem lengths in excess of 280m. and with te
ure differences > of 40 0C . pleasc、consull our Technicul SCI叫cc.
- Systems working 'v ith curves : lndicate the radius and degrccs. provide a skerch and service conditions. The minirnum
radius for horizonlal or vertical cur\'ei!. I m.
- Systems which rcquire inlensilies grcatcr lhan 140 Amps‘or Wilh morc lhan 4 poJes lhcy will require an assernbly 01' i arious housings in paralleJ.
- Syslems with divcrsions or mixed syslcms of oUldoor or indoor. lhey will be of anci l lary componen( applicalions. Consull our Technical
- InslalJalions wirh ambiel1t'> of humidily. acidity. lcmperalurc 。r olhers. plcase consul t.ëXAMPLE SKETCHES
更多商品
4-7.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM -07
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down load References : TO-4x35A TO-4x70A TO-4x35AC TO-4x70AC Jnsulalecl support. - Ball bearings. - Weighl TO-4x35A : 950 grrns. - Provided wirh 2m of extra-f1exible 4x4 mm2 cable. - Cable glund PG-16. - Spnng loaded c.:arbon brushes、 24x7λ22 mm in N51 quality. (rcf. ETO-4). For installations with transfer gllides、 !bey have precision travel with superior bealings. In these c泌的 ref. TO-4x35ATR‘il requires an elaslic towing ('.J'J11 ref. BA- 4TR. To enslIre power supply t.o thc 11l0bilc equipments at least two u'ol1eys ll1ust bc instulled. Max. spceds in m/rnin : TO-4x35A TO-4x35AC unù TO-4-J5ATR TO-4x70A TO-4x70AC and TO-4-70ATR TOWING ARM.4-6.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM -06
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down loadEN,D FEED Ref. AE-4,AE-4-100 aud AE-4-140 For connecting the power supply to rhe line al one end of the system. - 10 insulatcd material. - Wei且ht: 280 gnm,. -lncorporatcs the housin旦 conneclion日. - Cable emry ViH a cabJe glantl: - I pc. PG-21 for LM-40 日nd LM-60............ ReJ'. AE-4 - lpc. PG-29 for LM-80 and LM-100.......... Ref. AE-4-JOO - lpc. PG-36 [or LM-140............................. Ref. AE--l-- 140 - For outdoor syslems or aggressive environments Ref. AE-4E LIN E FIEeD Ref. AI-4,AI-4-100 and AI-4-140 For connecting the power supply at any position along the lenglh of the system. - In in:.ulated malerial. - Weight: 350 grms. - Wíth hou ing cυnnections which envclope the conductor èonnecllons. - Cable entry vi<1 cable glantl.s: - I pc. PG-21 for LM-40 and LM-60............ Ref. AT-4 - 2pc!>. PG-21 for LM-80 and LM-IOO........ Ref. AI-4-IOO -4pcs.PG-21 forLM-140........................... Ref.Al-4-140 - For ou tdoor systcrm,or a鋁ressive envirollmenl:. Ref. AJ-4EEND CAP Rcf.TE-4 Acts aJ,a security element prolecling the ends of the system. - In illsulared material. - Weighl: 130 grms.For outdoor syslem::, 01' aggres-;ive environmcnts Rer. TE-4E. FIXIED POINT ClAMP allowing free cxpallsion to bolh ends.Necessary to avoid total movement of the 月ystem and fOIRef. PF-4 - It is recommended that they 訂e instaJled in the cenlre of the syslem. - In galvanized steel. - Weight: 400 grms. For outdoor systems or aggressive environment,with epoxytratmcnt and screws made of stainlcss s!eel.4-5.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM -05
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down load For aggressive environments or outdoor iMnstallations,the connectio l1s are treated wüh cadmium,the screws are made of stainless steel and the sliding hangdUer are galvanized and cpoxy-coated. In these cases the system PEMY,80,PEM-100 andMODULAR HOUSING++Conneclion Piece Ref lnkuenvironmenls lhe re[erences are PEM-80E,PEM-IOOE and PEM-1 40E.references are LM-40E,LM-60E,LM-80E、LM-IOOE and LM-140E.conductors and incorporated connectio+n++ syslems. TheMPEM-140. PVC hous in g in 4 m. moduJes withlonger installalions. For outcloOJ systems SLl DING HANGER Ref. SO-4 - 111 ga l val1 ized steel. - The assembJy allows sliding 011 the hOllsing.- Weigh t: 210 gnns . For outdoor systems or aggressi ve environments, wh epoxy Lreatment and screws made of stai nJess steel. Ref. SO-4E. JOINT Ref. EMP-4 - In insulatecl matelial. - Weigh t: 180 grms. - The assembly al10ws sliding on the housing. For outdoor systems or aggressive env ironrnents‘ with screws made of stainJess steel. Ref. EMP-4E.4-4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM -04
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down load The starting intensÜy is consumed when 1l10tor 1S at sta tic rotor. It is a characteri stic of lhe motor a nd its value i s measured duri ng the motor tests. The norninaJ inten sity 1S a bsorbed wben the motor i s worhng at nominal power and is connected Ito a nominaJ voltage. The following equ ation gives its val ue: POWER FACTOR The power factor (Cos<p) is a quali ty electric factor of the motor. The rugher it is、l ess intensity wW be absorbecl to gi ve the same power. Its value indicates the "qu ality" of lhe motor related to its cons Ll mpti on. fts m ax imu ll1 vaJue will be 1. ORI ENTATT NG YALU ES FOR THE 4 POLES THREE-PHASE MOTO良 NOMI NAL CURR ENTS. ACCORDING TO NF C63- 1 J 0.1970. c.v K.W 220 V. 380 V 500 v. IAJIN 3 2,2 8,7 5 3 8 5 4 3 l1,5 6,6 5 5 5.5 4 1 4,5 8,5 6,5 5,2 7.5 5,5 20 1 1,5 9 3、4 10 7,5 27 15,5 1 2 5. 4 1 3,3 1 0 35 20 1 5 5,6 15 1 1 39 22 1 7 5.8 20 15 52 30 23 5.8 25 1 8,5 64 37 28,5 6 30 22 75 44 33 6 40 3Q l03 60 45 6,2 50 37 126 72.5 55 6.8 60 45 l 47 85 65 6. 8 75 55 L82 ]05 80 6,8 VOLTAGE DROl-" For three-phase alternating clment: .6U= Vo1t age c1rop in Volts. 1= AmpeI'age Ìli Amps. L= Length in m. z= Impecl ance ()f the conductors in 111m. Lenght lo be consi.derecl for the voltage drop caJ culation (System length= L): - Power supply in ()ne extreme= Ul - Power suppl y in rhe cen甘e= L/2 - Power supply in both extremes= Ll4 - Power supp]y at 1/6 from cach extrel11e= Ll6 The value of L is redLl cecl when the width of the mobi l e machine is con sidered. The system length jncludes the feedjng track length + feeding cable lenεth.4-3.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM -03
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down load REF. INTENSITY VOLTAGE IMPEDANCE Z between Voltage Drop*Distance Amp. V. Q/m. mm2 cond. m V/m/Amp. LM-40 40 500 2x10'3 9 15 0.00346一 LM-60 60 500 1.75x10>J 12 15 0.00303 LM-80 80 500 1.18x10.Q 16.5 15 0.00204 LM-100 100 500 1x10'3' 21 15 0.00173 LM-140 140 500 0.75χ10.3 30 15 0.001 234-2.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM -02
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down load Channelling elcClrical prOlection. with the use of Cllrrent displaccmcnl. Applicablc for seCll 扒旬,Like mobilc electric powcr supply wilh lïxed paths (straighl or curved) on : cranc , moving electrical machinery、 moving equipmcnt and in general, wherever ilis necessary 10 have mobilc powcr. Particulars: - Servicc securily . - Wilh a I) inglc moving asscmbly,the line remains scparated for use . - Any section of the system can be replaced. using 4111 scctions . - Discrctional extension of the system . - Powcr supply by cnd feed or by line feed . - Thermal expansion is absorbcd by each module. ClassificaLion uf LIII": ùegreeυf p lULectioll of the Modular System LM-4 ( CEI 144. DNI 324-89 ) : TP 237. 40 050 and UNE 20- Jntroduced in PVC diclcctric housing of four poles,carth pole i s rnarked with a yellow strip,in differenl versions according 10 inlcnsiries. WiLh assembJy of various parallcl syslems. obtaining he major number of polcs and higher ClllTenL capacily. Conductors freely installecl in thc hOllsing. permilting di仟erent expansions in lhe copper and thc PVC, likewise c1ispersion of the hcat providing for effecl Joule. Possibililies to asscmblc in incloors or in outdoors with service temperatllres between -30 0 and +60oC. For outcloor illstallation,thc mounting plan is c1í叮erent and thc sysrem componcnts are specialIy treated and screws are made 01' stainless stee,l SpeciaJ installations : Lenglh<; greater than 280 n1_ working curvcs. differenldiversions. mixed installations of outdoor-indoor ClC. consllllpage 8 and our Technical Services 、providing skclches and service conclitions.4-1.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM
4.LM-4盒型4心電軌LM-4 MODULAR CONDUCTOR SYSEM 下載down load3-2. 其他配件ACCESSORIES FOR HX CONDUCTOR BAR
3.HX電軌 HX CONDUCTOR BAR 下載down load 3-1. 密閉式HX電軌系統ENCLOSED CONDUCTOR BAR SYSTEM HX SERIES 3-2. 其他配件ACCESSORIES FOR HX CONDUCTOR BAR To provide an additionallevel of insulation,as well as rigid support of conductor sections,choose from polycarbonate snap.叭,steel clamp,or insulated hanger assemblies. Hanger assemblies accommodate a minimum conductor spacing of 4 inches.The Power Feed Kit includes a joint assembly and cable terminals for powerThis vinyl cover insulates the conductor bar at each end of a system. Web mounting brackets are available in 24 inch lengths with mounting holes punched every two inches. Mounting hardware is included.Collector assemblies are offered in single or double shoe designs.They provide contìnuous current pick up from 200 through 4 amperes. The contact shoes are mechanically supported by an insulating support assembly that is spring loaded by an arm and body mechanism. Collectors are furnished with copper graphite contacts for movement up to 9 feet per minute.