Provides a simple method for installing Side Contact Conductors on conveyors, monorails, bridges, crane runways and switches. These supports secure and separate the insulated conductors uniformly with a minimal amount of installation time. Hanger clamps are all stainless steel with 1/4” zinc plated hardware.
Consult Factory if you need a configurations not shown.
Single Bar, One Side of Beam
|
|
|
|
更多商品
1-5-7.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Power feed Fully insulated clamp is easily installed anywhere on the system for feeding power to the conductor bar. Description Part No. Wt lb (kg) Complete Assembly, Clamp & Case 11289 0.34 (0.15) Power feed case with hardware 11290 0.20 (0.09) Clamp Assembly 11291 0.10 (0.05) Pick-up Guides Used at the end of conductors to guide the re-engagement of the collectors on discontinu- Requires use of self-centering collectors, Description Part No. Wt lb (kg) For all systems (except 90A) 11292 1.25 (0.57)1-5-6.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Connector Pins Used to join the conductor bar together. Description Part No. Wt lb (kg) Galvanized steel for 110A 11120 0.8 (0.36) Copper for 250 and 350A 11121 0.8 (0.36) Galvanized steel for 90A 21914 0.8 (0.36) Stainless steel for 40A 24196 0.8 (0.36) Insulating Cover Available in PVC or Lexan cover. The cover is designed for indoor use. Description Part No. Wt lb (kg) Rigid PVC to 160O F 34579 1.5 (6.80) Medium Heat to 250O F 11294 1.5 (6.80) End Cover Used to close the end of the conductors to cover exposed conductor and avoid accidental contact. Description Part No. Wt lb (kg) For 40, 110, 250 and 350A 11295 0.03 (0.01) For 90A 24424 0.03 (0.01)1-5-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Stainless Clad Copper 250A Item Rigid PVC Cover Medium Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05m) 11227 7.0 ( 3.175) 11243 6.6 (2.994) Conductor Bar, 5 ft (1.52m) 11228 3.5 (1.588) 11244 3.3 (1.497) Expansion Section, 10 ft (3.05) 11256 11.0 (4.990) 11260 10.3 (4.672) Power feed 11289 0.34 (0.154) 11289 0.34 (0.154) End Cover 11295 0.03 (0.014) 11295 0.03 (0.014) Copper Steel Laminate 250A Item Rigid PVC Cover Medium Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05m) 11231 7.0 ( 3.18) 11247 6.6 (2.99) Conductor Bar, 5 ft (1.52m) 11232 3.5 (1.59) 11248 3.3 (1.50) Expansion Section, 10 ft (3.05) 11257 11.0 (4.99) 11261 10.3 (4.67) Power feed 11289 0.34 (0.15) 11289 0.34 (0.15) End Cover 11295 0.03 (0.01) 11295 0.03 (0.01) Electrolytic Copper 350A Item Conductor Bar, 10 ft (3.05m) Rigid PVC Cover Medium Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) 11235 7.0 ( 3.175) 11251 6.6 (2.994) Conductor Bar, 5 ft (1.52m) 11236 3.5 (1.588) 11252 3.3 (1.497) Expansion Section, 10 ft (3.05) 11258 11.0 (4.990) 11262 10.3 (4.672) Power feed 11289 0.4 (0.122) 11289 0.4 (0.122) End Cover 11295 0.03 (0.014) 11295 0.03 (0.014) Expansion Sections compensate for the thermal expansion that occurs from a combination of ambient heat and electrical heat. Power feeds and flexible jumpers are factory installed to meet electrical and mechanical requirements of each system. Part numbers are located in the conductor tables1-5-4.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadSide Contact Conductor Bars come with cover and connector pins installed. Copper and Laminate Bars also come with Joint Keepers. Bars are available in 40A, 90A, 110A, 250A, and 350A capacities (@ 600 volts maximum). Expansion Sections are listed below. These are required to compensate for thermal expansion; every 350 feet (106.7m) for 40A, 90A, and 110A systems, or 250 feet (76.2m) for 250A, 350A, and 500A systems. Power Feeds bring outside power to the conductor bar. Factory installed covers are available in: Rigid PVC: -10O F to 160O F (- 23.30 C to 71.10 C) Medium Heat: - 25O F To 250O F (- 31.70 C to 121.10 C) Stainless Steel, 40 Item Rigid PVC Cover Medium Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05m) 24273 7.0 ( 3.18) 24298 6.6 (2.99) Conductor Bar, 5 ft (1.52m) 24274 3.5 (1.59) 24299 3.3 (1.50) Expansion Section, 10 ft (3.05) 24277 10.0 (4.57) 24302 10.3 (4.67) Power feed 11289 0.34 (0.15) 11289 0.34 (0.15) End Cover 11295 0.03 (0.01) 11295 0.03 (0.01) Galvanized Steel, 90A Item Rigid PVC Cover Medium Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05m) 24275 4.5 (2.04) 24300 4.5 (2.04) Conductor Bar, 5 ft (1.52m) 24276 3.5 (1.59) 24301 3.3 (1.59) Expansion Section, 10 ft (3.05) 24278 6.7 (3.04) 24303 6.7 (3.04) Power feed 11289 0.34 (0.15) 11289 0.34 (0.15) End Cover 24424 0.03 (0.01) 24424 0.03 (0.01) Galvanized Steel, 110A Item Rigid PVC Cover Medium Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05m) 11223 7.0 ( 3.18) 11239 6.6 (2.99) Conductor Bar, 5 ft (1.52m) 11224 3.5 (1.59) 11240 3.3 (1.50) Expansion Section, 10 ft (3.05) 11255 10.0 (4.57) 11259 10.3 (4.67) Power feed 11289 0.34 (0.15) 11289 0.34 (0.15) End Cover 11295 0.03 (0.0) 11295 0.03 (0.01)1-5-3.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Shown below are some typical mounting arrangements for Side Contact. Trolleys on which collectors are mounted must be stabilized, particularly in systems involving discontinuous circuits. One acceptable way is to use guide rollers on the edge of the track flange.1-5-2.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Conductix-Wampfler Side Contact Conductor Bar is a variation of the 8-Bar system designed for lateral (side) entry of the collector. UL / CSA listed. Side Contact is Ideal When: There is insufficient room for standard "bottom entry" mounting • Conductors must be more closely spaced than standard 8-Bar Component Descriptions Conductor Bar: The supply of incoming power Power feed: Attachment of incoming power Collector: Collects the incoming power and transfers it to the moving machine Hangers: Supports the conductor bar, may also be used as an anchor to direct movement due to expansion and contraction End Cover: Safety protection at the end of conductor system1-5-1.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load1-4-23.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load