For straight system runs of 600V or less. For lateral mount, consult factory. The "Self-Centering" versions are used with Pick-up Guides - See
|
Replacement Shoe
100 amp replacement shoe 11157 0.9 ( 0.41)
For straight system runs of 600V or less, and curves to a minimum of 48” radius. For lateral mount, consult factory. The "Self-Centering" versions are used with Pick-up Guides - See
Description | Part No. | Wt lb (kg) |
Standard Mount | 13629 | 1.4 (0.65) |
Self-Centering Standard Mount | 13630 | 1.7 (0.77) |
|
|
Replacement Shoe
100 amp replacement shoe 11157 0.9 (0.41)
更多商品
1-4-16.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadSliding contact Collector Assemblies are offered in either single or double contact shoe types providing current capacities from 30A to 200A. Operational wear is confined to easily replaceable contact shoes. The shoes are supported by insulated holders on articulating, spring-loaded collector arms.For systems up to 600 volts with straight runs and curves to 18” minimum radius. For lateral mount, consult factory. The "Self-Centering" versions are used with Pick-up Guides - See Pg. 18. Type Part No. Wt lb (kg) Standard Mount 13128 2.5 (1.13) Tandem Standard Mount 13082 4.7 (2.13) Self-Centering Tandem Standard Mount 13084 4.9 (2.22) Self-Centering Standard Mount 13130 2.6 (1.180) Replacement Shoe 30 amp replacement shoe 13136 0.4 (0.18) For systems up to 600 volts with straight runs and curves to 18” minimum radius. For lateral mount, consult factory. The "Self-Centering" versions areused with Pick-up Guides - See Description Part No. Wt lb (kg) Standard Mount 13131 1.4 (0.64) Self-Centering Standard Mount 13132 1.7 (0.77) Replacement Shoe 30 amp replacement shoe 13136 0.4 (0.18)1-4-15.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Ordering Instructions: 1) Choose the desired bracket style by part number - See bracket styles below. 2) Also referring to the drawings below, choose the hole number locations at which hangers are to be assembled. Here is the recommended hanger spacing: Recommended Minimum Conductor Bar Spacing Indoor, inch (mm) Outdoor, inch (mm) 8 Bar (bottom entry) 2.0 (50.8) 3.0 (76.2) Side Contact (Lateral Mount) 3.0 (76.2) Not for outside use For less than 2.0” (50.8 mm) spacing, consult factory 3) Select desired hanger type by part number - From Pg. 19. 3) Select desired hanger type by part number - From Pg. 19. Example Order lines: Qty Part No. (Hole #'s) where hangers are to be mounted Description 10 31407 (1, 3, 5, 7) Web Bracket, Long (from below) 40 22800 Polycarbonate Snap Hanger (from Pg. 19) Note: When order is received, a unique part number will be created for the requested bracket/hangers combination. Bracket Hole Position Numbers: 1.0” (25.4 mm) Spacing Between Holes1-4-14.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadYou can order pre-assembled brackets with your choice of hangers on Pg. 21. Or, if these hanger locations don't work for the application, the "Universal Brackets" shown below should address most special applications. Holes are drilled on 1.0 inch (25.4 mm) centers. Type Length Part No. Wt lb (kg) Web Bracket, Short 11.5 (29) 31409 1.0 (0.45) Web Bracket, Long 15.5 (39) 31407 1.3 (0.59) Flange Bracket 18.0 (46) 31408 1.2 (0.54) Flange Bracket with Beam Clips 18.0 (46) 31418 1.6 (0.73) Flange Bracket with Beam Clips 24.0 (61) 31911 2.0 (0.91)1-4-13.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadBrackets w/Pre-Assembled Hanger Clamps The following brackets come with hanger clamps on 3” centers, brackets are zinc plated steel. Hanger Clamp styles are described With Polycarbonate Snap-In Hanger Clamps Without Insulators With Insulators Description Part No. Wt lb (kg) Part No. Wt lb (kg) Web type 5” 28829 2.0 (0.907) 51004 2.4 (1.09) Web type 9” 34189 3.1 (1.402) 50314 3.5 (1.59) Flange type, 2 hangers each side 51864 2.6 (1.179) 51865 3.1 (1.41) Flange type, 4 hangers on one side 51870 2.6 (1.179) 51871 3.1 (1.41) Steel Snap-In Hanger Clamps Without Insulators With Insulators Description Part No. Wt lb (kg) Part No. Wt lb (kg) Web type 6” 30281 1.6 (0.726) 51005 2.0 (0.91) Web type 9” 50312 2.7 (1.225) 50315 3.1 (1.41) Flange type, 2 hangers each side 51866 2.1 (0.953) 51867 2.5 (1.11) Flange type, 4 hangers on one side 51872 2.1 (0.953) 51873 2.5 (1.11) Cross-Bolt Hanger Clamps Without Insulators With Insulators Description Part No. Wt lb (kg) Part No. Wt lb (kg) Web type 6” 31762 2.0 (0.907) 29534 2.3 (1.04) Web type 9” 50312 3.1 (1.406) 50316 3.5 (1.59) Flange type, 2 51868 2.5(1.114) 51869 2.9(1.32)hangers each side Flange type, 4 51874 2.5 (1.114) 51875 2.9 (1.32) hangers on one side1-4-12.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadFor top running, web-mounted, bottom entry systems. Zinc plated steel. See Pg. 19 for hangers. Distance to First Hole: Part No. Wt lb (kg) 6.0 (152) 22014 2.4 (1.09) 9.0 (229); with three more holes - At 12.0 (305), 15 (381), and 18 (457) 29876 4.5 (2.04) For bottom entry monorail and under-hung systems, flange-mounted. Zinc plated steel. See Pg. 19 for hangers. Type Part No. Wt lb (kg) For 2 hangers each side 27762 2.5 (1.13) For 4 hangers on one side 27767 2.5 (1.13)1-4-11.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Hanger Clamps are designed to grip 8-Bar Conductors for stable support. Clamps are required every 5 foot (1.52m) standard. These Polycarbonate Snap-in Hanger Clamps are recommended for standard mount only; not recommended for curves or lateral mount. Type Hardware Part No. Wt lb (kg) Without Insulator Zinc Plated 22800 0.3 (0.14) Without Insulator Stainless Steel 23370 0.3 (0.14) With Insulator Zinc Plated 24405 0.3 (0.14) With Insulator Stainless Steel 28122 0.3 (0.14) The spring-steel Hanger Clamps are designed to grip 8-Bar Conductors for stable support. Clamps are required every 5 foot (1.52m) standard. Steel Snap- in Hanger Clamps are recommended for standard mounting; not recommended for curves or lateral mount. Type Part No. Wt lb (kg) Without Insulator 21600 0.2 (0.09) With Insulator 22000 0.3 (0.4) Cross-Bolt Hanger Clamps are designed to lock to 8-Bar Conductors for stable support. Hangers are required every 5’ for vertical entry, 3’ for curved systems and every 3’ 4” for lateral entry. Cross-Bolt Hanger Clamps are recommended for standard mounting, lateral mounting, and curved systems. Type Material Part No. Wt lb (kg) Without Insulator Plated Steel 11076 0.2 (0.11) Without Insulator Stainless Steel 11078 0.3 (0.14) With Insulator Plated Steel 11082 0.4 (0.18) With Insulator Stainless Steel 11084 0.4 (0.18) For standard mount, not recommended for curves or lateral mount. Type Material Part No. Wt lb (kg) Without Insulator Plated Steel 21833 0.3 (0.14) Without Insulator Stainless Steel 28123 0.3 (0.14) With Insulator Plated Steel 21982 0.5 (0.23) With Insulator Stainless Steel 28124 0.5 (0.23)1-4-10.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadUsed in switches and interlocks to accomplish smooth collector transfer. Item Description Part No. Wt lb (kg) End Transfer cap for 90A bar. 22070 0.03 ( 0.01) Left Transfer cap for 90A bar. 22395 0.03 ( 0.01) Right Transfer cap for 90A bar. 22396 0.03 ( 0.01) End Transfer cap for 40-350A bar 13161 0.03 ( 0.01) Left-hand cap for 40-350A bar 14118 0.03 ( 0.01) Right-hand cap for 40-350A bar 14119 0.03 ( 0.01) The Pick-up Guide allows the collector to leave the conductor and re-track upon return. Requires use of Self-Centering J-Head Collectors,Consult Factory for selection. Used: Part No. Wt lb (kg) Indoors, for 3” bar spacing 13142 1.75 (0.79) Indoors, for 4” bar spacing 11089 1.75 (0.79) Outdoors, for 3” bar spacing 13143 2.00 (0.91) Outdoors, for 4” bar spacing 11090 2.00 (0.91)1-4-9.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Required every 300 feet (94.1 m) for steel conductors or every 200 feet (61.0 m) for copper conductors to compensate for thermal expansion. Power feeds and flexible jumpers are factory installed to meet electrical and mechanical requirements of your system. Note: Part numbers are located in the Conductor tables Conductor isolation sections are used to electrically isolate control circuits, maintenance bays, etc. The kit includes 11127 Guide Assembly, PVC Cover, and Isolation Section for 40A to 350A (not including 90A). Consult our factory for proper selection. Part No. Wt lb (kg) 21841 2.3 (1.04) Components used for in-field modification. Description Part No. Wt lb (kg) Molded plastic insulating piece; only for 21841 11427 0.3 (0.14) Molded plastic 1” (25.4 mm) isolating pin. For 40-350A except for 90A; Two required per location. 11615 0.03 (0.01) Molded plastic, 1” (25.4 mm) isolating pin. For 90A only. Two required per location. 11618 0.03 (0.01) Galvanized Steel Guide Assembly. Provides rigid support at isolation areas. 11127 1.5 (0.68)