1-4-12.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄
1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load
1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load
1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load
1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load
1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load
1-6.CLUSTER電軌CLUSTER BAR 下載down load
For top running, web-mounted, bottom entry systems. Zinc plated steel. See Pg. 19 for hangers.
|
For bottom entry monorail and under-hung systems, flange-mounted. Zinc plated steel. See Pg. 19 for hangers.
|
更多商品
1-4-11.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Hanger Clamps are designed to grip 8-Bar Conductors for stable support. Clamps are required every 5 foot (1.52m) standard. These Polycarbonate Snap-in Hanger Clamps are recommended for standard mount only; not recommended for curves or lateral mount. Type Hardware Part No. Wt lb (kg) Without Insulator Zinc Plated 22800 0.3 (0.14) Without Insulator Stainless Steel 23370 0.3 (0.14) With Insulator Zinc Plated 24405 0.3 (0.14) With Insulator Stainless Steel 28122 0.3 (0.14) The spring-steel Hanger Clamps are designed to grip 8-Bar Conductors for stable support. Clamps are required every 5 foot (1.52m) standard. Steel Snap- in Hanger Clamps are recommended for standard mounting; not recommended for curves or lateral mount. Type Part No. Wt lb (kg) Without Insulator 21600 0.2 (0.09) With Insulator 22000 0.3 (0.4) Cross-Bolt Hanger Clamps are designed to lock to 8-Bar Conductors for stable support. Hangers are required every 5’ for vertical entry, 3’ for curved systems and every 3’ 4” for lateral entry. Cross-Bolt Hanger Clamps are recommended for standard mounting, lateral mounting, and curved systems. Type Material Part No. Wt lb (kg) Without Insulator Plated Steel 11076 0.2 (0.11) Without Insulator Stainless Steel 11078 0.3 (0.14) With Insulator Plated Steel 11082 0.4 (0.18) With Insulator Stainless Steel 11084 0.4 (0.18) For standard mount, not recommended for curves or lateral mount. Type Material Part No. Wt lb (kg) Without Insulator Plated Steel 21833 0.3 (0.14) Without Insulator Stainless Steel 28123 0.3 (0.14) With Insulator Plated Steel 21982 0.5 (0.23) With Insulator Stainless Steel 28124 0.5 (0.23)1-4-10.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadUsed in switches and interlocks to accomplish smooth collector transfer. Item Description Part No. Wt lb (kg) End Transfer cap for 90A bar. 22070 0.03 ( 0.01) Left Transfer cap for 90A bar. 22395 0.03 ( 0.01) Right Transfer cap for 90A bar. 22396 0.03 ( 0.01) End Transfer cap for 40-350A bar 13161 0.03 ( 0.01) Left-hand cap for 40-350A bar 14118 0.03 ( 0.01) Right-hand cap for 40-350A bar 14119 0.03 ( 0.01) The Pick-up Guide allows the collector to leave the conductor and re-track upon return. Requires use of Self-Centering J-Head Collectors,Consult Factory for selection. Used: Part No. Wt lb (kg) Indoors, for 3” bar spacing 13142 1.75 (0.79) Indoors, for 4” bar spacing 11089 1.75 (0.79) Outdoors, for 3” bar spacing 13143 2.00 (0.91) Outdoors, for 4” bar spacing 11090 2.00 (0.91)1-4-9.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Required every 300 feet (94.1 m) for steel conductors or every 200 feet (61.0 m) for copper conductors to compensate for thermal expansion. Power feeds and flexible jumpers are factory installed to meet electrical and mechanical requirements of your system. Note: Part numbers are located in the Conductor tables Conductor isolation sections are used to electrically isolate control circuits, maintenance bays, etc. The kit includes 11127 Guide Assembly, PVC Cover, and Isolation Section for 40A to 350A (not including 90A). Consult our factory for proper selection. Part No. Wt lb (kg) 21841 2.3 (1.04) Components used for in-field modification. Description Part No. Wt lb (kg) Molded plastic insulating piece; only for 21841 11427 0.3 (0.14) Molded plastic 1” (25.4 mm) isolating pin. For 40-350A except for 90A; Two required per location. 11615 0.03 (0.01) Molded plastic, 1” (25.4 mm) isolating pin. For 90A only. Two required per location. 11618 0.03 (0.01) Galvanized Steel Guide Assembly. Provides rigid support at isolation areas. 11127 1.5 (0.68)1-4-8.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadFor covering the exposed ends of 8-Bar Conductors. Used With 8-Bar Conductors: Max. Temp. 0 F ( 0C) Part No. Wt lb (kg) 40A, 110A, and 350A 300 (149) 11088 0.03 ( 0.02) 90A 400 (204) 22070 0.03 ( 0.02) 110A, 250A, 350A 400 (204) 11633 0.03 ( 0.02) 500A Solid Copper 160 (71) 12171 0.40 (0.02) 500A Solid Copper w/ Stainless Steel Hardware 160 (71) 27102 0.40 ( 0.02)Provides attachment of incoming power to the conductor rails. Fully insulated, simple clamp design for easy installation anywhere on the system. Current Cap. Clamp Matl Case Matl Max. Temp 0 F ( 0C) Part No. Wt lb (kg) 90 or 110 Steel Rigid PVC 160 (71) 11091 0.4 ( 0.18 ) 90 or 110 Steel Polyester 400 (204) 11122 0.4(0.18) 250 Copper Rigid PVC 160 (71) 11092 0.7 ( 0.32) 250 Copper Polyester 400 (204) 11093 0.7 ( 0.32 ) 500 Copper Polyester 400 (204) 11094 2.60 (1.19) 250 Copper Clamp w/Stainless Steel Hardware Rigid PVC 160 (71) 27104 0.7 ( 0.32 ) 500 Copper Clamp Polyester 400 (204.2) 27106 2.60 (1.19) w/Stainless Steel Hardware Description Part No. Wt lb (kg) Case & clip only. PVC 90/110, 250A 11131 0.2 ( 0.09) Case & clip only. High heat. 90/110, 250A 11132 0.3 ( 0.14) Case only. High heat 500A 11133 1.0 ( 0.45) Power Feed Clamp only. For Galvanized Steel, 90/110A 11128 0.1 ( 0.04) Power Feed Clamp only. For Copper, 250A 11129 0.4 (0.18) Power Feed Clamp only. For Copper, 500A 11130 1.6 (0.73)1-4-7.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down loadTo connect 500A solid copper conductor together. For all cover types. Description Part No. Wt lb (kg) Complete Assembly for Solid Copper 8-Bar 11117 1.5 (0.68) Connector Case Only 11118 0.5 (0.23) Connector Clamp Only 11119 1.0 (0.45) To secure and stabilize all copper conductor bar. Automatically included with the appropriate system at a nominal charge. Used With: Part No. Wt lb (kg) Rolled or laminated copper 8-Bar, 250A and 350A 11125 0.01 (0.004) To repair joints of damaged conductor bar. Used For: Part No. Wt lb (kg) 40A to 350A formed 8-Bar 24632 0.7 (0.32) High Heat Systems 51666 0.7 (0.32) Inserts into pre-punched holes of the conductor bar to pull conductor sections together securely. Supplied with the appropriate system at a nominal charge.1-4-6.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Meets all requirements for plastic electrical insulation and may be used indoors or outdoors. Covers are included with the conductors listed on Pgs. 12-13. Replacement length is 9 ft to 10.5 ft. (2.74m to 3.20m) Material Color Temp-Rating Part No. Wt lb (kg) Rigid PVC Orange -10O F to 160O F 11114 1.2 (0.54) Rigid PVC Green -10O F to 160O F 11114G 1.2 (0.54) UV Stable PVC Black -10O F to 160OF 11114B 1.2 (0.54) Medium Heat Lexan Red -25O F to 250O F 11115 0.8 (0.36) High Heat Polyester Dark Orange -60O F to 400O F 11116 1.7 (0.77) Used to connect two bar sections together. For quick and easy installation. Supplied with conductors listed on Pgs. 12-13. Two required per connection. Pin Used With: Material Part No. Stainless steel 40A 8-Bar Stainless steel 24196 Galvanized steel 90A 8-Bar Zinc plated steel 21914 Galvanized steel 110A 8-Bar Zinc plated Steel 11120 Rolled copper and laminated 8-Bar Copper 11121 3 in. (76mm) Transition Pin: For joining 90 to 110A 8-Bar Zinc plated steel 22885 Insulated protective covers for conductor bar joining parts. Automatically included with the conductors on Pgs. 12-13 at a nominal charge.1-4-5.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load Item Rigid PVC Cover Med Heat Cover High Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05 m) 11004 6.6 (2.99) 11023 6.2 (2.81) 11042 7.1 (3.22) Conductor Bar, 5 ft (1.52 m) 11005 3.3 (1.47) 11024 3.1 (1.41) 11043 3.6 (1.63) Expansion Section, 10 ft (3.05 m) 11059 8.5 (3.86) 11065 8.0 (3.63) 11071 9.2 (4.17) Power Feed 11092 0.7 (0.32) 11093 0.7 (0.32) 11093 0.7 (0.32) End Cover 11088 0.1 (0.05) 11088 0.1 (0.05) 11633 0.4 (0.18) Item Rigid PVC Cover Medium Heat cover High Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05 m) 11008 6.2 (2.81) 11027 5.8 (2.63) 11046 6.7 (3.04) Conductor Bar, 5 ft (1.52 m) 11009 3.1 (1.41) 11028 2.9 (1.32) 11047 3.4 (1.54) Expansion Section, 10 ft (3.05 m) 11060 10.0 (4.54) 11066 9.4 (4.26) 11072 10.8 (4.90) Power Feed 11092 0.7 (0.32) 11093 0.7 (0.32) 11093 0.7 (0.32) End Cover 11088 0.1 (0.05) 11088 0.1 (0.05) 11633 0.4 (0.18) Item Rigid PVC Cover Medium Heat Cover High Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05 m) 11012 7.0 (3.18) 11031 6.6 (2.99) 11050 7.5 (3.40) Conductor Bar, 5 ft (1.52 m) 11013 3.5 (1.59) 11032 3.3 (1.50) 11051 3.8 (1.72) Expansion Section, 10 ft (3.05 m) 11062 11.0 (4.99) 11068 11.0 (4.99) 11074 11.8 (5.35) Power Feed 11092 0.7 (0.32) 11093 0.7 (0.32) 11093 0.7 (0.32) End Cover 11088 0.1 (0.05) 11088 0.1 (0.05) 11633 0.4 (0.18) Item Rigid PVC Cover Medium Heat Cover High Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 20 ft (6.10 m) 11016 23.6 (10.71) 11035 22.1 (10.02) 11054 24.6 (11.16) Conductor Bar, 10 ft (3.05 m) 11017 11.8 (5.35) 11036 11.0 (4.99) 11055 12.3 (5.58) Expansion Section, 10 ft (3.05 m) 11063 18.5 (3.39) 11069 17.3 (7.85) 11075 20.0 (9.07) Power Feed 11094 2.6 (1.18) 11094 2.6 (1.18) 11094 2.6 (1.18) End Cover 12171 0.2 (0.09) 11633 0.2 (0.09) 11633 0.4 (0.18)1-4-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)
1.C&W電軌系統(SAF-T-BAR)新目錄 1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 下載down load 1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR) 下載down load 1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR) 下載down load 1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR) 下載down load 1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR) 下載down load 1-6.CLUSTER電軌CLUSTER BAR 下載down load 8-Bar conductor bars come with cover and connector pins installed. Bars are available in 40A, 90A, 110A, 250A, 350A, 500A capacities (@ 600 volts maximum). Expansion Sections are listed below. These are required to compensation for thermal expansion; every 350 feet (106.7 m) for 40A, 90A, and 100A systems or 250 feet (76.2 m) for 250A, 350A, and 500A systems. Power Feeds bring outside power to the conductor bar. Factory installed covers are available in: Rigid PVC: -10O F to 160O F (- 23.30C to 71.10C) Medium Heat: - 25O F To 250O F (- 31.70C to 121.10C) High Heat: - 60O F To 400O F (-51.10C to 204.20C) Item Rigid PVC Cover Med Heat Cover High Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05 m) 14299 7.0 (3.18) 24304 6.6 (2.29) 24307 7.5 (3.40) Conductor Bar, 5 ft (1.52 m) 14823 3.5 (1.59) 24305 3.3 (1.50) 24308 3.8 (1.72) Expansion Section, 10 ft (3.05 m) 24279 7.5 (3.40) 24306 7.0 (3.18) 24309 8.2 (3.72) Power Feed 11091 0.4 (0.18) 11091 0.4 (0.18) 11122 0.4 (0.18) End Cover 11088 0.1 (0.05) 11088 0.1 (0.05) 11633 0.1 (0.05) Item Rigid PVC Cover Med Heat Cover High Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05 m) 22135 4.4 (2.00) 22141 4.1 (1.86) 22147 4.9 (2.22) Conductor Bar, 5 ft (1.52 m) 22136 2.2 (1.00) 22142 2.1 (0.95) 22148 2.5 (1.14) Expansion Section, 10 ft (3.05 m) 22140 6.7 (3.31) 22146 6.3 (2.86) 22152 7.4 (3.36) Power Feed 11091 0.4 (0.18) 11091 0.4 (0.18) 11122 0.4 (0.18) End Cover 22070 0.1 (0.05) 22070 0.1 (0.05) 11633 0.1 (0.05) Item Rigid PVC Cover Med Heat Cover High Heat Cover Part No. Wt lb (kg) Part No. Wt lb (kg) Part No. Wt lb (kg) Conductor Bar, 10 ft (3.05 m) 11000 4.4 (2.00) 11019 4.1 (1.86) 11038 4.9 (2.22) Conductor Bar, 5 ft (1.52 m) 11001 2.2 (1.00) 11020 2.1 (0.95) 11039 2.5 (1.13) Expansion Section, 10 ft (3.05 m) 11057 6.7 (3.31) 11064 6.3 (2.86) 11070 7.4 (3.36) Power Feed 11091 0.4 (0.18) 11091 0.4 (0.18) 11122 0.4 (0.18) End Cover 11088 0.1 (0.05) 11088 0.1 (0.05) 11633 0.1 (0.05)