1-2-9.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)

商品名稱:

1-2-9.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)

詳細介紹:

1.C&W電軌系統(SAF-T-BAR)新目錄                                                                        
       1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR)                                               下載down load1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 
       1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)                                               下載down load1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)

       1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR)                                                下載down load1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR)

       1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)                                                  下載down load1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)

       1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)              下載down load1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)

       1-6.CLUSTER電軌CLUSTER BAR                                                                           下載down load 1-6.CLUSTER電軌CLUSTER BAR

Hanger clamp bracket should be attached to the runway beam by welding or bolting. Conductors should be spaced 5" (127 mm) inches apart, however, a minimum of 3.5" (89 mm) is acceptable. Hanger clamp brackets require 9/16"  (14.3 mm) holes for 1/2"  hanger clamp bolts.

 

To properly support the conductor and to keep standard rail overhang to 24" (610 mm), space the first two brackets on 6' (1.83 m) centers and all other brackets on 10' (3.05 m) centers.

 

The "Anchor" is a non-sliding version of the hanger which provides a solid fixing point on the conductor bar. Anchor clamp kit consists of an insulated keeper straddling each side of the standard hanger. The usual hanger bolt is replaced by a cup-point set screw that is tightened against the keeper plate at the desired anchor location. On HA1000H hangers, the set screw becomes the mounting bolt. ON HA1000K hangers, the set screw is threaded into the base of the insulator spool. HA1000PA anchors come with a drilled hole in the vertical stiffener. At the instal- lation site, a hole is drilled through the conductor bar to accommodate a threaded rod. Threaded rod is captured by acorn nuts on both sides of the clamp.

 

Hanger Clamp Type 2

Usage

Part No. 1

Wt lb (kg)

Hanger, coated steel

Normal atmospheres

HA1000H

0.5 (0.23)

Hanger, coated steel with insulator spool

Wet atmospheres

HA1000K

1.0 (0.45)

 

Hanger, Plastic

In lieu of:

HA1000H or HA1000K

HA1000P

0.5 (0.23)

Anchor, coated steel with anchor clamp kit

Normal atmospheres

HA1000HA

0.6 (0.27)

Anchor, coated steel with insulator spool and anchor clamp kit

Wet atmospheres

HA1000KA

1.1 (0.50)

Anchor, plastic with anchor clamp kit

 

HA1000PA

0.6 (0.27)

 

Suffix "A" indicates anchor options

All H Series components are available with stainless steel hardware, designated by the suffix "SS"