3-7.IMPULSE G+ /VG+ S3可調變頻天車控制器IMPULSE G+ /VG+ S3 ADJUSTABLE FRENQUENCY CRANE CONTROLS-7
3-7.IMPULSE G+ /VG+ S3可調變頻天車控制器IMPULSE G+ /VG+ S3 ADJUSTABLE FRENQUENCY CRANE CONTROLS-7
3.IMPULSE G+ /VG+ S3可調變頻天車控制器(新英文版) 下載down load
IMPULSE G+ /VG+ S3 ADJUSTABLE FRENQUENCY CRANE CONTROLS(NEW
English Version)
Certification UL, cUL (CE available upon request)
Rated input power supply volts 3-phase 200–240 or 380–480 Vac; 50 or 60 Hz and frequency
Allowable input voltage fluctuation +10% or -15% of nominal, 3-phase
Allowable input frequency fluctuation ±5% of nominal
Control method Fully digital; sine-wave, V/F control, open loop vector control,flux vector control
Maximum output voltage (Vac) Max output voltage 3-phase, 200/208/220/230/240V;
380/400/415/440/460/480V (proportional to input voltage)
Rated output frequency (Hz) 0 to 150 Hz (consult factory for applications above 150 Hz) Output frequency accuracy 0.01% — with digital reference command, -10° to 40°C;
0.1% — with analog reference command; 10 bits/10V; 25°C, ±10°C
Frequency reference resolution Digital: 0.01 Hz; analog: 0.03 Hz (at 60 Hz)
Output frequency resolution 0.01 Hz
Overload capacity 150% of rated load for 1 minute
Remote frequency reference sources 0–10 Vdc (20Ω); 4–20 mA (250Ω); ±10 Vdc; serial (RS-485) Acceleration/deceleration times 0.1 to 25.5 sec — 4 sets; 8 parameters are independently adjustable
Braking torque 150% or more with dynamic braking (optional)
Motor overload protection Electronic thermal overload relay; UL recognized (I2T)
Overcurrent protection level (OC) 200% of rated current
Circuit protection Ground fault and blown-fuse protection
Overvoltage protection level 410/820 Vdc
Undervoltage protection level 190/380 Vdc
Heatsink over temperature Thermostat trips at 105°C
Four quadrant torque limit selection Separate functions for FORWARD, REVERSE, REGEN; all selectable from
0–300%
Stall prevention Separate functions for acceleration, at-speed and constant horsepower region
Other protection features Speed deviation, overspeed, mechanical brake failure, lost output phase, lost input phase, failed-oscillator, PG-disconnect, mechanical overload, roll- back detection, internal braking transistor failure, and built in watchdog
DC bus voltage indication Charge LED is on until DC bus voltage drops below 50 Vdc
Location Indoors; requires protection from moisture, corrosive gases and liquids
Ambient operating temperature 14° to 113°F (-10° to 45°C) for open chassis (Consult factory for high ambient applications)
Storage temperature -4° to 140°F (-20° to 60°C)
Humidity 95% relative; noncondensing
Vibration 1 G 10 to 20 Hz; 0.2 G for 20-50 Hz
Elevation 3300 ft. (1000m) or less
Efficiency 96 to 98%
Displacement Power Factor 0.98
Twelve-Pulse Capability 30 to 125 HP @ 230 Vac, 30 to 500HP @ 460 Vac