1-1-15.SAF-T-BAR C型電軌(C SERIES CONDUCTOR)

商品名稱:

1-1-15.SAF-T-BAR C型電軌(C SERIES CONDUCTOR)

詳細介紹:

1.C&W電軌系統(SAF-T-BAR)新目錄                                                                        
       1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR)                                               下載down load1-1.SAF-T-BAR C型電軌(C SERIES CONDUCTOR) 
       1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)                                               下載down load1-2.SAF-T-BAR H型電軌(H SERIES CONDUCTOR)

       1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR)                                                下載down load1-3.SAF-T-BAR T型電軌(T SERIES CONDUCTOR)

       1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)                                                  下載down load1-4.INSUL-8 8字型電軌(INSUL-8 CONDUCTOR)

       1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)              下載down load1-5.INSUL-8側向8型電軌(INSUL-8 SIDE CONTACT CONDUCTOR BAR)

       1-6.CLUSTER電軌CLUSTER BAR                                                                           下載down load 1-6.CLUSTER電軌CLUSTER BAR


Amp Range            Drag

Shoe

Length

Contour

Curves?

Shoe

Thickness

Part No.

Case #

100-150          Normal

4.375

Blunt

None

0.21

150SI

150A

50-100           Normal

3.75

Tapered

None

0.19

70S

707-1

25-50             Light

3.00

Blunt

Short

0.19

35S

401A

100-125          Normal

3.75

Blunt

None

0.225

100S

601A100

Used to electrically isolate adjacent conductor sections with a 1/2”  over surface gap. The sleeve will support adjacent conductor sections, but must have hangers within 6” on each side of the isolation sleeve. Collectors bridge the gap electrically. Two sleeves separated

by 6” of conductor are required to prevent collectors from bridging the gap as in signal or control functions.

Part No.

Isolation Sleeve      CA100IS

Used for discontinuous circuits such as bridge controls, runway circuits at fire doors, etc., to allow collector to leave conductor and be realigned on return.  Works with all bar capacities. Use with self-centering  collectors only.

The guide is provided with hanger clamp and end cap. The guide itself is secured to the bracket with a 3/8"  bolt and the conductor is secured to the guide with a hanger

clamp.  Conductors must be mounted on 3" (76 mm) centers minimum. Install conductor one inch into guide throat.

 

Part No.

Pick-up Guide

CP100

Used to track the collector through bar misalignments of 1/8”  to ½” (3-13 mm) laterally and of up to 1/8” in the direction of contact. Self-centering collectors are not required, but dual collectors are required if power interruption cannot be tolerated.

 Conductors must be mounted on 3" (76 mm) centers minimum. Install conductor 1-1/2” (38 mm) into guide throat.

Part No. Transfer Guide       CT100